Iso15.GetSystemInformation

This command gets the system information of a VICC.

This commands is an optional command.

Properties

Parameters (request frame)

None

Returned values (response frame)

Name Type/Size Description
LabelStat Integer (8 bits) Status code returned from label. The following Bytes will only be returned, if LabelStat is OK.
Optional field, condition: LabelStat == 0x00
Info Bit mask (8 bits) -
RFU Integer (bit mask area 0xF0) Zero padding
EnICRef Boolean (bit 0x08) IC reference present / supported.
EnMemSize Boolean (bit 0x04) Memory size present / supported.
EnAFI Boolean (bit 0x02) AFI present / supported.
EnDSFID Boolean (bit 0x01) DSFID present / supported.
SNR Raw data (length 8 Bytes) -
Optional field, condition: (LabelStat == 0x00) and EnDSFID
DSFID Integer (8 bits) -
Optional field, condition: (LabelStat == 0x00) and EnAFI
AFI Integer (8 bits) -
Optional field, condition: (LabelStat == 0x00) and EnMemSize
BlockNum Integer (8 bits) Number of blocks - 1 (e.g. BlockNum = 0 means 1 block is present).
BlockSize Integer (8 bits) Block size - 1 in Byte (e.g. BlockSize = 0 means a block size of 1 Byte).
Optional field, condition: (LabelStat == 0x00) and EnICRef
ICRef Integer (8 bits) -